Part Number Hot Search : 
1N5528 BH2221FV HR868 E1201 MHL9125D 1T365 TS10P03G HPA14
Product Description
Full Text Search
 

To Download BCR16PM-12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 BCR16PM
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Isolated Triac
16 Amperes/400-600 Volts
OUTLINE DRAWING
C 5.2
1.2 D
J
A
E H
Description: A triac is a solid state silicon AC switch which may be gate triggered from an off-state to an on-state for either polarity of applied voltage.
B G N L M L P K
F CONNECTION DIAGRAM
Features: Full Molded Isolation Package Glass Passivation Low Off-state Leakage 1500 VRMS Isolation Voltage UL Card Excellent Surge Capability Low On-state Voltage Selected for Inductive Loads Applications: AC Switch Motor Controls Lighting TV SSR Ordering Information: Example: Select the complete eight, nine or ten digit part number you desire from the table - i.e. BCR16PM-8 is a 400 Volt, 16 Ampere Triac.
Type BCR16PM VDRM Volts 400 600 Code -8 -12 Inductive Load* L
T1 TERMINAL T2 TERMINAL GATE TERMINAL
Outline Drawing (Conforms to TO-220F) Dimensions A B C D E F G Inches 0.67 0.49 Min. 0.39 0.33 0.20 0.18 0.14 Millimeters 17.0 12.5 Min. 10.0 8.5 5.0 4.5 3.6 Dimensions H J K L M N P Inches Millimeters
0.126 0.008 Dia.3.2 0.2 Dia. 0.11 0.102 0.10 0.039 0.031 0.020 2.8 2.6 2.5 1.0 0.8 0.5
*For inductive load, add L.
T-79
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR16PM Isolated Triac 16 Amperes/400-600 Volts
Absolute Maximum Ratings, Ta = 25 C unless otherwise specified
Ratings Repetitive Peak Off-state Voltage Non-repetitive Peak Off-state Voltage On-state Current, Tc = 71C Non-repetitive Peak Surge, One Cycle (60 Hz) I2t for Fusing, t = 8.3 msec Peak Gate Power Dissipation, 20 sec Average Gate Power Dissipation Peak Gate Current Peak Gate Voltage Storage Temperature Operating Junction Temperature Isolation Voltage Weight Symbol VDRM VDSM IT(RMS) ITSM I2t PGM PG(avg) IGM VGM Tstg Tj Viso - BCR16PM-8 400 500 16 160 106.5 5 0.5 2 10 -40 to 125 -40 to 125
1500
BCR16PM-12 600 720 16 160 106.5 5 0.5 2 10 -40 to 125 -40 to 125
1500
Units Volts Volts Amperes Amperes A2sec Watts Watts Amperes Volts C C
Volts
2
2
Grams
Electrical and Thermal Characteristics, Tj = 25 C unless otherwise specified
Characteristics Gate Parameters DC Gate Trigger Current MT2+ Gate+ MT2+ Gate- MT2- Gate- DC Gate Trigger Voltage MT2+ Gate+ MT2+ Gate- MT2- Gate- DC Gate Non-trigger Voltage All VGD 1/2 VDRM - - 125C 0.2 - - Volts VFGT I VRGT I VRGT III 6V 6V 6V 6 6 6 330 330 330 25C 25C 25C - - - - - - 1.5 1.5 1.5 Volts Volts Volts IFGT I IRGT I IRGT III 6V 6V 6V 6 6 6 330 330 330 25C 25C 25C - - - - - - 30 30 30 mA mA mA Symbol Test Conditions (Trigger Mode) VD RL RG Tj Min. BCR16PM Typ. Max. Units
Characteristics Thermal Resistance, Junction-to-case Voltage - Blocking State Repetitive Off-state Current Current - Conducting State Peak On-state Voltage Critical Rate-of-rise of Commutating Off-state Voltage (Commutating dv/dt) v for inductive load (L) (Switching)
Symbol Rth(j-c) IDRM VTM (dv/dt)c
Test Conditions - Gate Open Circuited, VD = VDRM, Tj = 125C Tc = 25C, ITM = 25A -
Min. - - - -
Typ. - - - -
Max. 3 2 1.6 -
Units C/W mA Volts V/ s
T-80
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR16PM Isolated Triac 16 Amperes/400-600 Volts
MAXIMUM ON-STATE CHARACTERISTICS
INSTANTANEOUS ON-STATE CURRENT, IT, (AMPERES) TRANSIENT THERMAL IMPEDANCE, Zth(j-c), (C/WATT)
TRANSIENT THERMAL IMPEDANCE, Zth(j-a), (C/WATT)
4.4
Tj = 25oC Tj = 125oC
102 5
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION-TO-CASE) 103
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION-TO-AMBIENT)
103
NO FINS
3.6
4
102
2.8
3
101
2.0
2
100
1.2 0.6 100
1 0 10-1
101
102
103
100
101
102
10-1 101
102
103
CYCLES AT 60 Hz
104
105
INSTANTANEOUS ON-STATE VOLTAGE, VT, (VOLTS)
CYCLES AT 60 Hz
GATE CHARACTERISTICS (I, II, III)
MAXIMUM PEAK SURGE CURRENT, ITSM, (AMPERES)
MAXIMUM SURGE CURRENT FOLLOWING RATED LOAD CONDITIONS
ALLOWABLE CASE TEMPERATURE VS. RMS ON-STATE CURRENT
102
VGM = 10V
GATE VOLTAGE, VG, (VOLTS)
200
160 140
CASE TEMPERATURE, TC, (C)
PG(avg) = 0.5W PGM = 5W
160
120 100 80 60 40 20
FOR AC CONTROL THIS GRAPH NEARLY APPLIES REGARDLESS OF THE CONDUCTION ANGLE
101
VGT = 1.5V IRGT I, IFGT I, IRGT III VGD = 0.2V IGM = 2A
120
360 CONDUCTION RESISTIVE, INDUCTIVE LOADS
80
100
40
10-1 101
102
103
104
0 100
0 101
CYCLES AT 60 Hz
102
0
4
8
12
16
20
GATE CURRENT, IG, (mA)
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
ALLOWABLE AMBIENT TEMPERATURE VS. RMS ON-STATE CURRENT
MAXIMUM ON-STATE POWER DISSIPATION
GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
160
MAXIMUM POWER DISSIPATION, (WATTS)
40 35 30 25 20 15 10 5 0 0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2
RMS ON-STATE CURRENT, IT(RMS), (AMPERES) 360 CONDUCTION RESISTIVE, INDUCTIVE LOADS GATE TRIGGER CURRENT, (tC) x 100% GATE TRIGGER CURRENT, (25C)
103
140
AMBIENT TEMPERATURE, Ta, (C)
NATURAL CONVECTION, NO FIN ARBITRARY CONDUCTION ANGLE RESISTIVE, INDUCTIVE LOADS
120 100 80 60 40 20 0
102
101 0 2 4 6 8 10 12 14 16 18 20 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C) RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
T-81
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR16PM Isolated Triac 16 Amperes/400-600 Volts
GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
BREAKOVER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
x 100%
BREAKOVER VOLTAGE VS. RATE OF RISE OF OFF-STATE VOLTAGE (TYPICAL)
103
GATE TRIGGER VOLTAGE, (tC) x 100% GATE TRIGGER VOLTAGE, (25C) BREAKOVER VOLTAGE, (tC) x 100% BREAKOVER VOLTAGE, (25C)
160 140 120 100 80 60 40 20 0 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C) JUNCTION TEMPERATURE, Tj, (C)
160 140 120 100 80 60
#1 #2 Tj = 125C I QUADRANT III QUADRANT
102
BREAKOVER VOLTAGE, (dv/dt = x V/ s) BREAKOVER VOLTAGE, (dv/dt = 1V/ s)
40 20 0 101 102 103 104
101 -60 -40 -20 0 20 40 60 80 100 120 140
REPETITIVE PEAK OFF-STATE CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
REPETITIVE PEAK OFF-STATE CURRENT, (tC) x 100% REPETITIVE PEAK OFF-STATE CURRENT, (25C)
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ s)
COMMUTATION CHARACTERISTICS (TYPICAL)
GATE TRIGGER CURRENT VS. GATE CURRENT PULSE WIDTH (TYPICAL)
105
CRITICAL RATE OF RISE OF OFF-STATE COMMUTATING VOLTAGE, (V/ s)
103
t (dv/dt)c VD
104
102
CURRENT WAVEFORM IT (di/dt)c t
MINIMUM CHARACTERISTICS VALUE
GATE TRIGGER CURRENT, (tw) x 100% GATE TRIGGER CURRENT, (DC)
Tj = 125oC IT = 4A = 500 s VD = 200v f = 3Hz
103
VOLTAGE WAVEFORM
102
I QUADRANT
103
101
III QUADRANT
Tj = 25C IFGT I IRGT I IRGT III
102 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C)
100 100
101
102
103
101 100
101
GATE CURRENT PULSE WIDTH, tw, ( s)
102
RATE OF DECAY OF ON-STATE COMMUTATING CURRENT, (A/ms)
GATE TRIGGER CHARACTERISTICS TEST CIRCUITS
6 A 6V V
6 A V
RG 6V
RG
Part Number BCR16PM-8L
Commutating dv/dt, (dv/dt)c VDRM (V/msec) (Volts) Load Type Minimum Test Condition 400 L L 10 10 Tj = 125C, Rate of Decay On-state Commutating Current (di/dt)c = -8A/msec; Peak Off-state Voltage VD = 400V
Commutating Voltage & Current Waveform (Inductive Load)
SUPPLY VOLTAGE MAIN CURRENT MAIN VOLTAGE (dv / dt)C
TEST PROCEDURE I
TEST PROCEDURE II
BCR16PM-12L 600
t (di / dt)C t VD t VD
6 A 6V V
RG
TEST PROCEDURE III
T-82


▲Up To Search▲   

 
Price & Availability of BCR16PM-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X